How to read a certificate of analysis
A certificate of analysis is the laboratory report for a single batch. Here is what each section records, how to match it to your vial, and the gaps that should make you ask questions.
5 min read

A certificate of analysis (COA) is a report from a testing laboratory on one batch of material. It says what was tested, how, when and what was found. For a research peptide, it is the main evidence that the powder in the vial is the compound named on the label, and of how much of that powder is the compound rather than something else.
Layouts vary, but most COAs contain the same parts. This guide covers them in the order you are likely to meet them.
Start with the batch code
The first check is the simplest. A COA should name a batch (or lot) code, and that code should match the one printed on your vial. A COA without a batch code tells you about some material, tested at some point. It tells you nothing about the vial in front of you.
Every THE GROUP vial carries a batch code, and you can look up the COA for that code on our COA page.
The header
The top of a COA usually gives:
- the product name, and often its sequence, molecular formula or expected molecular weight
- the batch code
- the dates: when the material was made (if known), when it was tested, and a retest or expiry date
- the name and address of the laboratory that carried out the tests
- the name of the person who reviewed and approved the report, with a date
If the testing laboratory is not named, you cannot check its accreditation or contact it with a question.
Appearance
The table of tests often starts with appearance, for example "white lyophilised powder". It is the simplest test on the page, but if your vial doesn't match it, ask the supplier before going further.
Identity: is it the right molecule?
Identity is usually confirmed by mass spectrometry (MS), often coupled to liquid chromatography (LC-MS). The instrument measures the mass of the molecules in the sample. A good COA shows the expected mass, calculated from the peptide's sequence, next to the observed mass, and the two should agree within the tolerance the laboratory states.
Mass spectrometry tells you the main component has the right mass. It does not, on its own, tell you how pure the sample is. That is a separate test.
Purity: how much of the sample is the main peptide?
Peptide purity is normally measured by high-performance liquid chromatography (HPLC), usually reversed-phase HPLC with UV detection at a low wavelength, typically 214 or 220 nm, where peptide bonds absorb light. The sample is separated into peaks as it passes through the column. Purity is reported as the area of the main peak as a percentage of the total area of all the peaks.
A useful COA includes the chromatogram itself, showing the main peak and any smaller impurity peaks, and the method: the column, the gradient and the detection wavelength. A purity figure with no chromatogram is much harder to check.
HPLC purity has a limit worth knowing. It describes the proportion of the peptide material that is the target peptide. It is not the same as peptide content by weight. A lyophilised powder also holds some water, and counter-ions left over from purification, such as acetate or trifluoroacetate (TFA). Some COAs report peptide content or water content as separate tests. If yours doesn't, the purity figure alone won't tell you how much of the powder's weight is peptide.
Other tests you may see
Depending on the product and the laboratory, a COA may also report:
- water content, often by Karl Fischer titration
- counter-ion content, such as TFA or acetate
- peptide content, by amino acid analysis or nitrogen analysis
- bacterial endotoxin, which matters for some cell-culture work
Not every COA covers all of these. A COA should only list tests that were actually carried out on that batch.
Accreditation
Some testing laboratories are accredited to ISO/IEC 17025, the international standard for the competence of testing and calibration laboratories. In the UK, the national accreditation body is UKAS. Accreditation covers specific methods rather than everything a laboratory does, so if it matters to you, check that the laboratory's schedule of accreditation includes the test in question.
Signs to look out for
Ask questions if you see any of the following:
- no batch code, or a code that doesn't match your vial
- no laboratory name, or no test date
- a purity figure with no chromatogram or method details
- identical figures and chromatograms on COAs for different batches (real batches vary slightly)
- a test date that is earlier than the batch could have been made
- an image that looks edited, cropped or blurred where the details should be
A supplier should be able to tell you which laboratory tested a batch and send you the original report.
How we publish COAs
At THE GROUP, the COA for a batch is linked from the product page while that batch is on sale, and you can look up any batch by the code on its vial on our COA page. We don't quote purity figures unless a batch COA backs them. If something on one of our COAs isn't clear, email us with the batch code and we'll explain it.
THE GROUP research products are supplied for laboratory research use only. Not for human or veterinary use.


